
$120.85$150.99
Prepare to embark on a sensory journey with the Bosco Apple, a fruit that transcends the ordinary and promises an unparalleled taste experience. These apples are nothing short of nature’s masterpiece, celebrated for their distinctive blend of flavors and their captivating visual allure.
Availability: In Stock
Harmony, Modular multifunction 3-phase supply control relay, 5 A, 2 CO, 220...480 V AC
| range of product | Harmony Control Relays |
|---|---|
| Relay type | Multifunction control relay |
| Product specific application | For 3-phase supply |
| Relay name | RM35TF |
| Relay monitored parameters | Undervoltage and overvoltage in window mode Phase sequence Phase failure detection Asymmetry |
| Measurement range | 220...480 V AC |
| time delay | Adjustable 0.1...10 s, +/- 10 % of the full scale value Tt- time delay upon fault |
| Output contacts | 2 C/O |
| Nominal output current | 5 A |
| Contacts type and composition | 2 C/O |
| [Uc] control circuit voltage | 220...480 V |
| [Un] rated nominal voltage | , self-powered |
|---|---|
| Supply voltage limits | 194…528 V AC, 3 phases |
| Reset time | 1500 ms at 480 V |
| Maximum switching voltage | 250 V AC 250 V DC |
| Switching capacity in VA | 1250 VA |
| Minimum switching current | 10 mA at 5 V DC |
| Maximum switching current | 5 A AC 5 A DC |
| Control circuit voltage limits | - 12 % + 10 % Un |
| Power consumption in VA | 0…22 VA at 400 V AC 50 Hz |
| Voltage detection threshold | < 194> |
| Control circuit frequency | 50...60 Hz +/- 10 % |
| Measurement voltage limits | 176…528 V AC |
| Hysteresis | 2 % |
| delay at power up | 650 ms |
| Maximum measuring cycle | 140 ms measurement cycle as true rms value |
| Threshold adjustment voltage | 2...20 % of Un selected -12...-2 % in the range 220 V AC +2...+10 % in the range 480 V AC |
| Voltage range | 220...480 V phase to phase |
| Adjustment of asymmetry threshold | 5...15 % of Un selected |
| Repeat accuracy | 0.3 % for time delay 0.5 % for input and measurement circuit |
| Measurement error | < 1> 0.05 %/°C with temperature variation |
| Response time | < 200> |
| Insulation resistance | > 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1 |
| [Ui] rated insulation voltage | 400 V conforming to IEC 60664-1 |
| Supply frequency | 50/60 Hz +/- 10 % |
| Operating position | Any position without derating |
| Connections - terminals | Screw terminals, 1 x 0.5...1 x 4 mm⊃2; (AWG 20...AWG 11) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm⊃2; (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm⊃2; (AWG 24...AWG 12) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm⊃2; (AWG 24...AWG 16) flexible with cable end |
| Tightening torque | 0.6…1 N.m conforming to IEC 60947-1 |
| Housing material | Self-extinguishing plastic |
| Local signalling | LED (green) for power ON LED (yellow) for relay ON LED (yellow) for fault |
| Mounting support | 35 mm symmetrical DIN rail conforming to IEC 60715 |
| Electrical durability | 100000 cycles |
| Mechanical durability | 30000000 cycles |
| Operating rate | <= 360 operations/hour full load |
| Utilisation category | AC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 |
| Safety reliability data | MTTFd = 399.5 years B10d = 360000 |
| Width | 35 mm |
| net weight | 0.13 kg |
| Control type | Without test button |
| Electromagnetic compatibility | Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to IEC 61000-6-2 |
|---|---|
| Standards | IEC 60255-1 |
| Product certifications | GL UL CSA GOST C-Tick |
| marking | CE |
| Directives | 89/336/EEC - electromagnetic compatibility 73/23/EEC - low voltage directive |
| Ambient air temperature for storage | -40…70 °C |
| Ambient air temperature for operation | -20…50 °C |
| Relative humidity | 95 % at 55 °C conforming to IEC 60068-2-30 |
| Vibration resistance | 0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6…150 Hz) conforming to IEC 60255-21-1 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60255-21-1 |
| IP degree of protection | IP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529 |
| Pollution degree | 3 conforming to IEC 60664-1 |
| Overvoltage category | III conforming to IEC 60664-1 |
| Dielectric test voltage | 2 kV, 1 min AC 50 Hz |
| Non-dissipating shock wave | 4 kV |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 4.800 cm |
| Package 1 Width | 7.800 cm |
| Package 1 Length | 9.700 cm |
| Package 1 Weight | 133.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 48 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 7.070 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 384 |
| Package 3 Height | 75.000 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 64.124 kg |
| Warranty | 18 months |
|---|